Product Details:
|
Low voltage electrode steam boiler
1. Principle and characteristics
1.1.The heating principle is the same as that of the high-voltage electrode boiler, which uses the high resistance of water to directly heat the water through the current.
1.2.The working voltage is 380V, three-phase connection, and the current is directly guided into the water between the three-phase electrode and the zero-position electrode. The power is achieved by adjusting the conductivity in the furnace.
1.3.The feed water is softened water with a conductivity (25℃) of 300-1300us/cm, which reduces the reverse osmosis device compared to the high-voltage electrode boiler.
1.4.The low-voltage electrode steam boiler is composed of a low-voltage electrode steam boiler, a feed water pump, a water softener and a control system.
1.5.Compared with the resistance boiler, it has high thermal efficiency, anti-dry burning function, and the boiler body is safely grounded.
1.6.It can be directly connected to 380V low-voltage electricity, without high-voltage electricity, and occupies a small area.
1.7.Modular design, easy installation and maintenance.
1.8.Power range: 0.1t/h-3t/h.
2. Performance parameters - 1.3MPa
Model |
LDJ-0.1 |
LDJ-0.2 |
LDJ-0.3 |
LDJ-0.4 |
LDJ-0.5 |
LDJ-0.7 |
LDJ-0.8 |
LDJ-1.0 |
LDJ-1.2 |
LDJ-1.4 |
LDJ-1.6 |
||||
Rated steam pressure |
1.3MPa |
1.3MPa |
1.3MPa |
1.3MPa |
|||||||||||
Steam(t/h) |
0.1 |
0.2 |
0.3 |
0.4 |
0.5 |
0.7 |
0.8 |
1.0 |
1.2 |
1.4 |
1.6 |
||||
Power(KW) |
100 |
150 |
200 |
300 |
300 |
500 |
600 |
700 |
800 |
1000 |
1100 |
||||
Length*Width(m) |
1.5*1.2 |
1.5*1.2 |
1.5*1.2 |
1.5*1.2 |
1.5*1.5 |
1.5*1.5 |
1.5*1.5 |
1.5*3 |
1.5*3 |
1.5*3 |
1.5*3 |
||||
Height(m) |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
||||
Steam outlet size |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
DN50 |
||||
Water inlet size |
DN20 |
DN20 |
DN20 |
DN20 |
DN20 |
DN20 |
DN20 |
DN25 |
DN25 |
DN25 |
DN25 |
||||
Shipping Weight(kg) |
150 |
150 |
150 |
300 |
300 |
400 |
600 |
600 |
900 |
900 |
900 |
||||
Operating weight(kg) |
180 |
180 |
180 |
360 |
360 |
480 |
720 |
720 |
1100 |
1100 |
1100 |
||||
Gas supply pressure |
≤1.3MPa |
≤1.3MPa |
≤1.3MPa |
≤1.3MPa |
|||||||||||
Voltage |
380V |
380V |
380V |
380V |
3. System Introduction
3.1.The low-voltage electrode steam boiler is composed of a low-voltage electrode steam boiler, a feed water pump, a desuperheater, a water softener and a control system.
3.2.Compared with the resistance boiler, it has high thermal efficiency, anti-dry burning function, and the boiler body is safely grounded.
3.3.It can be directly connected to 380V low-voltage electricity, without high-voltage electricity, and occupies a small area.
3.4.The boiler power is controlled by the output current of the electric control system. Modular design, easy installation and maintenance.